LOY YANG AGL POWER STATION

Structural Issues: Included cracking to top ring of 120m cooling towers, spalling concrete and corroded structural support braces, expansion joints and external cladding.

Scope of Work:

  • Installation of one ton swing stage support frames
  • Helicopter hover exits
  • Emergency Make safe to spalling concrete
  • Painting
  • Welding
  • Internal duct inspections and structural support brace repairs

 

Benefits of Rope Access:

  • Cost effective – eliminating the need for complex scaffolding
  • Safe and efficient

 

Job facts:

  • Install of 1t swing stage support frames to top ring of 120m cooling tower
  • Crack injection, concrete patch repair and core sampling to hyperbolic structure
  • Confined space welding repairs to internal structural support braces and expansion joints
  • External cladding repairs to square and round duct work including expansion joints

 

Quality, Safety & Environment:

  • Detailed safe work method statements, rescue plans and daily safety brief
  • Adhered to site specific confined space procedures
  • Independent safety audits completed
  • Personal gas monitoring