Cauldron Energy
Location:
Barrys Reef. Blackwood, Victoria
Work Description: Use of Cardox explosive systems to excavate both height and width an area of the gold mine deemed by the client for…
Opal Australian Paper Mill
Location:
Maryvale. Victoria
Work description: Absafe installed an ATD Cardox blasting system including fill station and operational equipment as well as carrying out all field works related…
Wagners Cement
Location:
Brisbane Queensland
Work description: The Absafe Cardox team was engaged to assist in the clearance of both the Gypsum tank & Vertical Mill Inlet Shute at…
Northern Beaches Rope Access Pty Ltd
Location:
Potts Point Sydney
Work description: Cavity flashing replacements at level 5 on 8 level building Notable fact about product/service: Ronin worked first time with no hiccups. Speed…
55 Islington Street, Collingwood
Location:
55 Islington Street Collingwood
Work Description: Upon completion of this set of high-rise units & townhouses, it was identified that the rooftop did not have any anchor points…
Holmesglen Campus
Location:
Holmesglen
Work description: Working with Holmesglen TAFE & RACV Solar, Absafe installed height safety access system on more the x10 Holmesglen building when new solar…
Tomahawk Creek Works
Location:
Tomahawk creek. Simpson.
Work description: Demolition and removal of 16 concrete support piers and 5 lateral supporting piers. Site welding of new steel supporting brackets as per…
Kangaroo Creek Dam
Location:
Kangaroo Creek Dam, Adelaide Hills, South Australia
THE ISSUE: Kangaroo Creek Reservoir is an artificial water storage reservoir in Adelaide Hills, South Australia. The dam was built in 1969 and is…
HAZELWOOD POWER STATION CHIMNEY REPAIRS
Location:
Hazelwood, Vic
APPLICATION USED: The Hazelwood Power Station is a now decommissioned brown coal-fuelled thermal power station located in the Latrobe Valley of Victoria, Australia. Due…
HAZELWOOD POWER STATION
Location:
Hazelwood, VIC
Structural Issues: Above top gantry gunnite shotcrete replacement of 140 metre chimney Delaminated and spalling concrete patches up to 44 square metre below top…
LOY YANG AGL POWER STATION
Location:
Loy Yang, VIC
Structural Issues: Included cracking to top ring of 120m cooling towers, spalling concrete and corroded structural support braces, expansion joints and external cladding. Scope…
2 AND 50 LONDSDALE STREET
Location:
Melbourne CBD, VIC
Structural Issues: Damaged façade to both buildings with signs of corrosion and missing pieces/items Scope of Work – 2 Lonsdale Street: Concrete repairs Replacement…
THE MELBURNIAN APARTMENTS
Location:
Melbourne, VIC
Structural Issues: The leading edge balcony I-beams were showing signs of rust. Investigations revealed a construction phase design fault. Scope of Work: Remediation of…
271 COLLINS STREET
Location:
Melbourne CBD, VIC
Issues: Exterior coating had deteriorated over the years, a new colour was chosen to modernise the building. Scope of Work: Priming and painting of…
131 LONSDALE STREET
Location:
Melbourne CBD, Victoria
Structural Issues: It was unknown when the building had been previously painted. The external coating was in poor condition and the balcony balustrades had…
COLLINS BRIDGE
Location:
Collingwood, VIC
Structural Issues: Signs of corrosion at the node junctions, bolt penetrations and I-beam surface Scope of Work: Structural Improvements Industrial Coatings Concrete Repairs Benefits…
YALLOURN POWER STATION
Location:
Yallourn, VIC
Structural Issues: Corroded, separated and missing internal duct support braces Delaminated and spalling concrete creating imminent fall hazards to cooling tower and stacks Corroded…
395 COLLINS STREET
Location:
Melbourne CBD, VIC
Structural Issues: During inspection sand stone and granite pillars were found to be partially detached Scope of Work: Carry out inspection and makesafe to…
621 SWANSTON STREET
Location:
Melbourne CBD, VIC
Removal and disposal of all fixed positioned combustible alucobond panels across the buildings northern, eastern and southern facades. …
RAILTON DEVONPORT CEMENT SILOS
Location:
Railton and Devonport, TAS
Enabled access to silos without alterations to structure. Safer personnel extraction than traditional methods. Cost effective – eliminating the need for complex scaffolding….